BoX2 pro
High-performance protocol converter/IIoT gateway/edge controller
- Protocol conversion
- Cloud connectivity
- HMI and web server
- Local data base storage, alarm servers, data exchange, reporting, C# scripting
- UL/cUL Class I Division 2
Facts
General description
Part number | 100-0974 |
Life cycle status | Active |
Warranty | 2 year |
Features
Protocol conversion | Yes |
Cloud connectivity | Yes |
HMI web server | Yes |
Local data base storage | Yes |
C# scripting | Yes |
Alarm server | Yes |
Certifications
General | CE, FCC, KCC |
Hazardous | ULC1D2 |
Marine | LR, ABS, BV, DNV GL |
Safety | UL 61010-2-201 |
Mechanical
DIN rail/mounting plate |
Power
Input voltage | 24VDC (18-32V DC) |
Power consumption (max) | 5W |
Input fuse | 3,14 AT |
CPU | i.MX6DualLite Dual Cortex-A9 1.0GHz 512kBL2cache |
RAM | 1 GB |
FLASH | 2GB SSD(eMMC), 1.5GB free for application |
Serial communication
Number of serial ports | 1 Port 9pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS 485 |
Ethernet communication
Number of Ethernet ports | 2 |
Ethernet port 1 | 1×10/100 Base-T (shielded RJ45) |
Ethernet port 2 | 1×10/100 Base-T (shielded RJ45) |
Expansion interface
SD card | SD and SDHC |
USB | 1xUSB 2.0 500mA |
Environmental
Operating temperature | -10°C to +60°C |
Storage temperature | -20°C to +70°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP20 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Altitude (max) | < 3000m |
Drivers
ABB – COMLI Master (5.7.2) |
ABB – COMLI Slave (4.11.0) |
ABB – TotalFlow (5.2.1) |
Allen Bradley – ControlLogix Ethernet IP (4.24.1) |
Allen Bradley – DF1 (5.8.0) |
Allen Bradley – DH485 (4.6.2) |
Allen Bradley – MicroLogix Ethernet (5.6.0) |
Allen Bradley – SLC5/PLC5 Ethernet (5.4.0) |
Altus – Alnet I (5.8.0) |
Animatics – SmartMotor (5.2.1) |
Beckhoff – ADS (5.12.1) |
Beckhoff – ADS Symbolic (4.7.0) |
Beijer Electronics – iX Demo (4.4.0) |
Beijer Electronics – Macro driver (4.0.7) |
Bernecker + Rainer – Mininet (5.6.0) |
BoschRexroth – IndraDrive C (5.2.1) |
CODESYS – ARTI v2.x, v3.x (4.8.0) |
CODESYS – SoftControl Direct Access (4.4.0) |
Cognex – InSight (5.2.2) |
Control Techniques – Unidrive (5.3.1) |
CTC – Serial Binary (5.4.2) |
Delta – PLC Modbus ASCII (5.6.0) |
Emerson – Modbus Master RTU/ASCII (5.4.0) |
Eurotherm – Easy Serial 631 (5.1.1) |
Fatek – Facon (5.10.0) |
Galil – DMC (5.2.2) |
GE Fanuc – Ethernet SRTP (5.5.0) |
GE Fanuc – SNPX (5.6.1) |
Gidding & Lewis – Motion control (5.4.0) |
IAI – Xsel (5.4.1) |
Idec – Computer Link (5.8.0) |
Johnson Control – JCONTROL (5.2.1) |
KEB – COMBIVERT (5.4.0) |
Keyence – KV-series (5.6.0) |
Koyo – DirectNET (5.5.0) |
Koyo – K Sequence (5.3.1) |
Lenze – LECOM A/B (5.6.0) |
LS Industrial System – Glofa (5.3.0) |
LS Industrial System – Master K (5.4.0) |
Matsushita – MEWTOCOL-COM (5.9.2) |
Mitsubishi Electric – Alpha2 (5.7.0) |
Mitsubishi Electric – A-series (C24) (5.6.0) |
Mitsubishi Electric – A-series (CPU) (5.10.0) |
Mitsubishi Electric – A-series (E71) (5.4.0) |
Mitsubishi Electric – Freqrol FR-A PLC (5.8.2) |
Mitsubishi Electric – FX Series ADP/BD (5.10.0) |
Mitsubishi Electric – FX Series ENET (5.4.1) |
Mitsubishi Electric – FX Series Serial (5.16.0) |
Mitsubishi Electric – MC Protocol (5.11.4) |
Mitsubishi Electric – MR-J2/MR-J3-T MELSERVO (5.9.0) |
Mitsubishi Electric – QnA/Qnn Serial (5.10.0) |
Mitsubishi Electric – QnA/Qnn (C24) (5.5.0) |
Mitsubishi Electric – Q-Series Ethernet (E71) (5.5.0) |
Modicon – Modbus Master (5.19.4) |
Modicon – Modbus Slave RTU/TCP (4.20.2) |
NEMA0183 – NEMA 0183 (4.6.0) |
Omron – Ethernet IP (4.3.3) |
Omron – FINS (5.9.5) |
Omron – Host Link (5.6.0) |
Regin – EXOline (5.3.2) |
SAIA – S-BUS Serial/Ethernet (5.7.0) |
Schneider Electric – Modbus (5.3.0) |
Schneider Electric – TSX Uni-Telway (4.5.3) |
Siemens – S5 PG/AS511 (5.4.0) |
Siemens – S7 200 PPI (5.8.5) |
Siemens – S7 over TCP (S7-200/300/400/1200/1500) (4.18.0) |
Siemens – MPI (HMI Adapter) (5.7.0) |
WAGO – Modbus TCP (5.10.0) |
Vigor – M/VB-Series (5.6.0) |
Yamaha – VIP (5.2.1) |
Yaskawa – Memobus Master (5.7.0) |
Yokogawa – FA-M3 (5.6.0) |
Smart Engineering Resources
Resources
Certificates
- DoC CE, EMC, RoHS Declaration of conformity X2 pro, X2 control, X2 marine , X2 web, Box 2 pro
- BoX2 pro (SC) / BoX2 extreme (SC) DNV – GL Type Approval Certificate
- BoX2 pro (SC), BoX2 extreme (SC) – ABS Type Approval Certificate
- DNV Type Approval Certificate BoX2 pro BoX2 extreme
- BoX2 pro (SC) / BoX2 extreme (SC), SAFE COMPASS DISTANCE INFORMATION,
- IECEx Certificate X2 extreme (SC) / BoX2 extreme (SC)
- BoX2 pro (SC) / BoX2 extreme (SC) – BV certificate for
- CE certification, BoX2 base – BoX2 pro – BoX2 extreme
- BoX2 base / BoX2 pro / BoX2 extreme FCC – Verification of compliance
Knowledge
- Box2 base / BoX2 pro (SC) / BoX2 extreme (SC), unknown IP \ reset \ reformat
- Best Practice Image update for X2 pro, X2 marine and BoX2 pro 2.1 HF, MAEN361
- BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC) LED indication
- BoX2 Erase / Delete Project with USB
- Box2 Diagnostics, manual and LED
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909 (current)
- X2 pro (SC) / X2 marine (SC) / X2 extreme (SC) / BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC), Battery replacement
- X2/BoX2 script Access to the USB ports
Configuration files
Manuals
- BoX2 pro (SC) Installation Manual, MAEN275
- X2/Box2 image manual MAEN205
- BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC), Image Manual, MAEN205 rev C
Product information
System program
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909 (current)
- X2 pro / X2 marine / BoX2 pro, image V2.0 b773 (Obsolete)
- X2 pro / X2 marine / BoX2 pro image V1.5 (Obsolete)