BFI-H3-22-0070-3F12-MN
Article number 62411
- Output power 1.5 kW
- Output 3×230 VAC, 7.0 A
- Input voltage 3×200-240 VAC
- IP20
Facts
General description
Article number | 62411 |
Warranty | 2 year |
Mechanical
IP class | IP20 |
Physical size | Size 2 |
Measurements (H x W x D) | 221 mm x 110 mm x 185 mm |
Weight | 1,8 kg |
Typical power loss at rated power | 2 % of rated power |
Main switch | No |
Built in Main switch, control switch and potentiometer | No |
Conformal coated PCBs | Yes, IEC 60721-3-3, 3S2/3C2 |
Output ratings
Output voltage | 3 x 230 VAC |
Rated motor current | 7,0 A |
Overload capacity | 110% for 60 seconds, 165% for 4 seconds |
Motor power | 1.5 kW |
Output frequency | 0 – 250Hz, 0.1Hz resolution |
Supported motor types | 3 phase AC induction (IM), AC permanent magnet (PM), Brushless DC (BLDC), Synchronous reluctance (SynRM) |
Built-in brake transistor | No |
Regenerative capacity | No brake transistor |
Input ratings
Supply voltage | 200 – 240VAC ± 10% |
Voltage fluctuations | +/- 10% |
Phase imbalance | 3% maximum allowed |
Displacement factor | > 0.98 |
Supply frequency | 48 – 62Hz |
Power cycles | 120 per hour maximum, evenly spaced |
Total harmonic current distorsion | EN61000-3-12 |
Control specification
Control modes | Variable torque V/F, Variable torque energy optimised V/F, Constant torque U/F, Sensorless Vector Speed Control, Synchronous Reluctance Motor Control, Brushless DC Motor Control, Open Loop PM Vector Control |
Current/torque limitation | Torque and current limitation |
PWM frquency | 4-32 kHz effective |
Stopping mode | Ramp to Stop: User Adjustable 0.1 – 6000 seconds. Fast stop. Coast to Stop |
Braking | Motor Flux Braking |
Skip frequency | Yes |
Analog setpoint control | 0 to 10V, 10 to 0V, −10 to 10V, 0 to 20mA, 20 to 0mA, 4 to 20mA, 20 to 4mA |
Digital setpoint control | 8 fixed speeds, Motorised Potentiometer, Internal PLC, Keypad, Modbus RTU, BacNet, Optional: PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCat, PROFINET, Modbus TCP, CC-Link |
Communication
Modbus RTU | Yes, 9.6 – 115.2 kbps (8N1, 8N2, 8E1, 8O1) |
BACnet MS/TP | Built-in |
Modbus TCP | Yes, external option |
Ethernet IP | Yes, external option |
EtherCat | Yes, external option |
Profinet IO | Yes, external option |
Profibus DP(DPV1) | Yes, external option |
Device Net | Yes, external option |
CC-Link | Yes, external option |
CAN open | No |
Display
Programmable display | Yes |
Multi language OLED display | TFT Display |
External OLED display | Yes, TFT Display |
LED display | No |
HVAC
PID-control | Yes with sleep/wake up functionality |
Spin start | Yes |
Pump dry protection | Yes |
Pump prime and burst protection | Yes |
Stir function | Yes |
Motor pre-heat | Yes |
Broken impeller and broken belt detection | Yes |
Automatic cleaning for pumps | Yes |
Bypass control | Yes |
Fire mode | Yes |
Control terminals
Power supply | 100 mA @ 24 VDC, 20 mA @ 10 VDC |
Inputs | 5 in total, 3 Digital, 2 Analog or Digital, selectable |
Digital inputs | 10-30 V DC, PNP, Response time: < 4 msec, Internal or external supply |
Analog inputs | Resolution:12 bit, Response time: <4 msec; Accuracy: <± 2% of full scale, Adjustable scaling |
Outputs | 4 total, 2 relays, 2 analog or digital |
Digital transistor outputs | 24VDC/20 mA, Internal supply |
Relay outputs | Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity: 6A AC, 5A DC |
Analog outputs | 0 to 10 Volt, 0 to 20mA, 4 to 20mA |
Safety inputs | 2 |
Extra IOs | Yes, internal option |
Control features
Speed control Master/slave | Yes, Master and slave |
Modbus master functionality | Yes, Master and slave |
Advanced hoist control | No |
Built-in PLC | Yes |
Standard compliances
Low voltage directive | 2014/35/EU |
EMC directive | 2014/30/EU |
Conformance | CE, UL, cUL |
Machine directive | 2006/42/EC |
Marine approvals | No |
Safe torque OFF | Cat 3/PL”d” According to ISO 13849-1, SIL CL 2 According to EN61800-5-2 / EN62061 / IEC61508 |
Restriction of hazardous substances | RoHS2 |
Registration evaluation and authorisation of chemicals | Reach |
Harmonics | EN 61000-3-12 |
Earth leakage current | EN 61800-5-1: 2007. Test techniques EN 60990:2000. 1×230 VA < 2,5 mA, 3x400VAC < 4,65 during runing |
DC Bus discharge time | EN 61800-5-1:2007 |
Electrostatic discharge | EN 61800-3:2004+A1-2012. Test techniques EN 61000-4-2:2009. |
Dielectric strength | 61800-5-1: 2007 |
Surge | EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-5:2006. |
Electrical fast transient burst | EN 61800-3: 2004+A1-2012. Test techniques EN 61000-4-4:2004. |
Ambient conditions
Temperature operation | -10 to 50 °C |
Humidity | 95% max, non-condensing |
Maintenance
Fault memory | Last 4 Trips stored with time stamp |
Data logging | Logging of data prior to trip, Current, Temperature, DC Bus Voltage |
Maintenence indicator | Yes. Onboard service life monitoring |
Monitoring | Hours Run Meter, kWh/MWh meter |
Resources
Knowledge
- Alarm code running single phase motor with 3-phase output BFI
- Alarm, Excessive DC-rippel
- 24 VAC connected to terminal 1 will damaged the drive
- Input Phase Loss Detection
- Alarm O-I Instantaneous over current on drive output
- Alarm, INHIBIT
- Application Note BFI-H3, Fire Mode Operation
- Application Note BFI-H3, Bypass Operation
- Application note BFI-H3. Pump clean function
- Application note BFI-H3. Multi Pump Cascade control, DOL
- Application Note BFI-H3, Locking Parameters to Prevent Changes
- OLED Remote External Keypad, Working with Multiple Drive Networks
- Profibus contacts for BFI-P2 and BFI-H3
- Single phase motors run by BFI-E3/H3/P2
- DC-ripple
- Fans, external cooling fans
- Application Note BFI-H3, Optiflow Multi Pump Cascade Control
- Application Note BFI-H3, Setting the Motor Nameplate Details
- PID-control. Scaling of actual processvalue in display and unit
- BFI-H3, PID reference/setpoint from Fieldbus
- Modbus RTU and Modbus TCP communication at the same time
- Thermal protection inside motor connected to BFI-E3/P2/H3
- Emergency runing by a digital signal when normal running by Fieldbus/Ethernet
- Application Note BFI-H3, PID-control
- Application Note BFI-H3, Setting up Acceleration and Deceleration Ramp Rates
- Application Note BFI-H3, Setting the Required Stopping Mode
- CC-Link communication
- Forced manual control when runing Fieldbus control
- BFI cable connectors fork type
- BFI p2 e3 h3 hand control manual control
Drawings
- Cable CAB114: Cable for ModBus RS485 between Nexto Xpress and BFI
- Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
- CAD drawings: BFI-H3 IP66 (step and dwg)
- CAD drawings: BFI-H3 IP55 (step and dwg)
- CAD drawings: BFI-H3 IP20 (step and dwg)
- BFI connection into Modbus RTU or CANopen network
Certificates
- Manufacture Declaration for US and Canada
- Manufacturer declaration: BFI-H3 Declaration of Conformity CE
- Conflict Minerals Policy Statement
- Ecodesign for BFI Frequency Inverters
- Modern Slavery Act Company Statement
- RoHS 3, Restriction of Hazardous Substances. September 2021.
- REACH Directive Compliance Statement, September 2021
- Manufacturer declaration: BFI-H3 UKCA Declaration of Conformity
- Manufacturer declaration: UKCA Declaration of Conformity, Options for BFI
- Manufacturer declaration: CE Declaration of Conformity, Options for BFI
Data sheets
- Datasheet: Input AC Line chokes to BFI
- Datasheet: Sine wave filter
- Datasheet: Output chokes for BFI
- Datasheet: External EMC-filters for BFI
- Datablad Extern parameterenhet OPT-2-OPPAD-BFI
- Datablad Kablage för Modbus RTU mot BFI
- Specification of all BFI, Functions/Hardware
- Datasheet Isolator switch option for BFI-P2 IP55
- Datasheet Additional option board with 3 additional realy outputs
- Datasheet Additional option board with 3 digital inputs and one relay output
Brochures
Program examples/Start-up
- Program example BCS Tools and iX: Nexto communication with BFI by EtherCAT
- Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
- Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
- Program example CODESYS and iX: X2 Control communication with BFI-P2/BFI-H3 by Modbus TCP
- Program example CODESYS and iX: X2 Control communication with BFI by Modbus RTU
- Program example CODESYS and iX: X2 Control communication with BFI by EtherCat
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus TCP
- Program example BCS Tools and iX: Nexto Xpress communication with BFI by Modbus RTU.
Manuals
- Manual Modbus RTU RS-485- communication
- Manual Profibus DP BFI-P2 and BFI-H3
- Manual BFI-Tools, PC-software for BFI
- Manual BFI-Smartstick for programming by Bluetooth
- Manual User Guide BFI-H3 (English) ver 3.08
- Kom-Igång dokument BFI-H3, Swedish
- Start-Up-Document Frequency Inverter BFI-H3 (KI00363D)