X2 control 15
15” HMI with iX runtime and CODESYS soft control
- 1280 × 800 pixel (16:10) TFT-LCD touch screen
- 1.5 GB application memory
- Ethernet 2×100 Mbit
- EtherCAT as standard
- CODESYS control integrated
- CE, FCC, KCC, UL approvals
- DNV GL, KR, LR, ABS, CCS, BV, NK, RS marine approvals
Facts
General description
Part number | 640002405 |
Life cycle status | Active |
Warranty | 2 year |
Certifications
General | CE, FCC, KCC, UL 61010-2-201 |
Marine | KR, LR, ABS, BV, CCS, NK, DNV GL, RS |
Safety | UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201 |
Mechanical
Mechanical size | 410 x 286 x 61mm |
Panel Mount, VESA 75 x 75 | |
1million finger touch operations | |
Touch type | Resistive |
Cut-out size | 394 x 270mm |
Weight | 3.85 kg |
Housing material | Powder-coated aluminum, Gray |
Power
Input voltage | 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies. |
Power consumption (max) | 31.2W |
Input fuse | Internal DC fuse |
CPU | i.MX6Quad, Quad ARMCortex-A9 1.0GHz 1MBL2cache |
RAM | 2 GB |
FLASH | 2GB SSD(eMMC), 1.5GB free for application |
Display
Size diagonal | 15.4″ diagonal |
Resolution | 1280×800 pixels |
Backlight | LED Backlight |
Backlight life time | 50000 hours |
Backlight brightness | 450 cd/m2 |
Backlight dimming | Industrial Dimming |
Display type | TFT-LCD with LED backlight |
Softcontrol
Codesys runtime version | 3.5 |
Codesys EtherCAT | Yes |
Codesys Modbus Ethernet | Yes |
Codesys Modbus RTU | Yes |
CANopen | Yes |
Non volatile variables | 64 KB |
Digtal IO
Digital output | 2xDO Solid state relay, 0.5A@24VDC |
Serial communication
Number of serial ports | 1 Port 9pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS485 (only if COM 2 is RS485) |
Ethernet communication
Number of Ethernet ports | 2 |
Ethernet port 1 | 1×10/100 Base-T (shielded RJ45) |
Ethernet port 2 | 1×10/100 Base-T (shielded RJ45) |
2 | |
0.5 MBit | |
0.5 MBit |
Expansion interface
Expansion port | Yes, ciX expansion module |
SD card | SD and SDHC |
USB | 2xUSB 2.0 500mA |
Environmental
Operating temperature | -10°C to +60°C |
Storage temperature | -20°C to +70°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP65, NEMA 4X/ 12 and UL 50E Type 4X/ 12 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Drivers
ABB – COMLI Master (5.7.2) |
ABB – COMLI Slave (4.11.0) |
ABB – TotalFlow (5.2.1) |
Allen Bradley – ControlLogix Ethernet IP (4.24.1) |
Allen Bradley – DF1 (5.8.0) |
Allen Bradley – DH485 (4.6.2) |
Allen Bradley – MicroLogix Ethernet (5.6.0) |
Allen Bradley – SLC5/PLC5 Ethernet (5.4.0) |
Altus – Alnet I (5.8.0) |
Animatics – SmartMotor (5.2.1) |
Beckhoff – ADS (5.12.1) |
Beckhoff – ADS Symbolic (4.7.0) |
Beijer Electronics – iX Demo (4.4.0) |
Bernecker + Rainer – Mininet (5.6.0) |
BoschRexroth – IndraDrive C (5.2.1) |
CAN – FreeCan (J1939/NMEA2000) (5.3.5) |
CAN – CANopen (5.4.0) |
CODESYS – ARTI v2.x, v3.x (4.8.0) |
CODESYS – SoftControl Direct Access (4.4.0) |
Cognex – InSight (5.2.2) |
Control Techniques – Unidrive (5.3.1) |
CTC – Serial Binary (5.4.2) |
Delta – PLC Modbus ASCII (5.6.0) |
Emerson – DNP3 (4.8.2) |
Emerson – Modbus Master RTU/ASCII (5.4.0) |
Eurotherm – Easy Serial 631 (5.1.1) |
Fatek – Facon (5.10.0) |
Galil – DMC (5.2.2) |
GE Fanuc – Ethernet SRTP (5.5.0) |
GE Fanuc – SNPX (5.6.1) |
Gidding & Lewis – Motion control (5.4.0) |
IAI – Xsel (5.4.1) |
Idec – Computer Link (5.8.0) |
Johnson Control – JCONTROL (5.2.1) |
KEB – COMBIVERT (5.4.0) |
Keyence – KV-series (5.6.0) |
Koyo – DirectNET (5.5.0) |
Koyo – K Sequence (5.3.1) |
Lenze – LECOM A/B (5.6.0) |
LS Industrial System – Glofa (5.3.0) |
LS Industrial System – Master K (5.4.0) |
Matsushita – MEWTOCOL-COM (5.9.2) |
Mitsubishi Electric – Alpha2 (5.7.0) |
Mitsubishi Electric – A-series (C24) (5.6.0) |
Mitsubishi Electric – A-series (CPU) (5.10.0) |
Mitsubishi Electric – A-series (E71) (5.4.0) |
Mitsubishi Electric – Freqrol FR-A PLC (5.8.2) |
Mitsubishi Electric – FX Series ADP/BD (5.10.0) |
Mitsubishi Electric – FX Series ENET (5.4.1) |
Mitsubishi Electric – FX Series Serial (5.16.0) |
Mitsubishi Electric – MC Protocol (5.11.4) |
Mitsubishi Electric – MR-J2/MR-J3-T MELSERVO (5.9.0) |
Mitsubishi Electric – QnA/Qnn Serial (5.10.0) |
Mitsubishi Electric – QnA/Qnn (C24) (5.5.0) |
Mitsubishi Electric – Q-Series Ethernet (E71) (5.5.0) |
Modicon – Modbus Master (5.19.4) |
Modicon – Modbus Slave RTU/TCP (4.20.2) |
NEMA0183 – NEMA 0183 (4.6.0) |
Omron – Ethernet IP (4.3.3) |
Omron – FINS (5.9.5) |
Omron – Host Link (5.6.0) |
Regin – EXOline (5.3.2) |
Profibus – Profibus DP (5.5.1) |
SAIA – S-BUS Serial/Ethernet (5.7.0) |
Schneider Electric – Modbus (5.3.0) |
Schneider Electric – TSX Uni-Telway (4.5.3) |
Siemens – S5 PG/AS511 (5.4.0) |
Siemens – S7 200 PPI (5.8.5) |
Siemens – S7 over TCP (S7-200/300/400/1200/1500) (4.18.0) |
Siemens – MPI (HMI Adapter) (5.7.0) |
Siemens – MPI (CiX) (5.3.0) |
WAGO – Modbus TCP (5.10.0) |
Vigor – M/VB-Series (5.6.0) |
Yamaha – VIP (5.2.1) |
Yaskawa – Memobus Master (5.7.0) |
Yokogawa – FA-M3 (5.6.0) |
Smart Engineering Resources
Resources
Knowledge
- IX otf and ttf fonts
- iX Developer SP7 – 2.47.473 Release information
- Driver MODICON Modbus Slave: Command XDNCW
- Windows CE versions, X2, iX, E1000
- Creating a custom Welcome Screen \ startup screen on a X2 pro operator panel
- Google Gmail end suport for ” less secure apps ” ends may 30 2022
- iX – SMTP – Using Gmail servers using App password
- When are Data deleted from the ix x2 database / backup restore database
- OPC ua settings in Phoenix plxnext engineer
- Image Sticking
- Best Practice Database on SD card or flash memory
- Driver Allen Bradley DF1: Behövs 1747-KE kommunikationsmodul ?
- Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411
- Max number of recipe items / tags
- Convert from Exter/E1000 To X2 Series
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909 (current)
- X2 Preemptive maintenance
- X2 image – Update EBOOT require SD card to be formatted to FAT16/FAT32
- X2 pro (SC) / X2 marine (SC) / X2 extreme (SC) / BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC), Battery replacement
- X2/BoX2 script Access to the USB ports
- General handling of positions with Beijer servo products
- Beijer Electronics – Device Runtime and Compiler versions in CODESYS
- CODESYS – Modbus RTU Dynamic Configuration
- Handling of software limits – SoftMotion vs SoftControl
- Handling of modulo positioning – SoftMotion vs SoftControl
- Codesys – Enable/Disable Modbus RTU slaves from IEC code
- X2 control/pro CAN bus limitations (HW rev. 1)
- X2 control / X2 extreme SC / X2 marine SC / BoX2 pro SC / BoX2 extreme SC, firmware / systemprogram vs Codesys runtime version
Manuals
- iX Developer SP7 – 2.47.473 Reference Manual
- iX Developer SP7 – 2.47.473 User guide
- X2/Box2 image manual MAEN205
- Installation Manual X2 pro, X2 marine, X2 control MAxx202
- Installation manual for X2 control 15 – B2, MAEN349 English
Certificates
- DoC ECCN for X2 series HMI
- SDoC Green Passport
- Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
- FCC Verification X2 control
- DoC Green Passport Declaration
- DoC CE, EMC, RoHS Declaration of conformity X2 pro, X2 control, X2 marine , X2 web, Box 2 pro
- DNV certification X2 pro, X2 marine, X2 control
- ABS PDA certification X2 pro, marine, control, motion
- LR Type approval certificate X2 pro, X2 marine, X2 control, X2 motion
- Compass safe distance X2 pro/control/motion/marine
- ABS Type certification X2 pro, X2 marine, X2 control
- Manufacturer declaration: X2 pro marine control UKCA Declaration of Conformity
- CE Verification X2 control
- BV Type approval certificate X2 pro, X2 marine, X2 control, X2 motion
- RS certification X2 pro, X2 marine, X2 control
- CCS Marine Certificate X2 extreme, pro, control, marine
- KR certification X2 pro, X2 marine, X2 control, X2 motion
- NKK certificate X2 pro, X2 marine, X2 control, X2 motion
- KCC, MSIP Certificate, X2 control 15, X2 motion 15, X2 marine 15 SC
Drawings
- Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
- CAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
- CAB112 Cable Drawing for X2 control, TxA/TxB SoftControl
- CAB111 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B operator panel
- CAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
- CAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
- Cable CAB154: Cable for CANopen between X2 Control and BFI
- CAB153 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
- CAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
- CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
- Outline drawing, X2 pro 15, X2 marine 15, X2 control 15, X2 motion 15
- 3D drawing, X2 pro 15, X2 marine 15, X2 control 15, X2 motion 15 in STEP format
- Cutout drawing, X2 pro 15, X2 marine 15, X2 control 15, X2 motion 15,
Drivers
Brochures
Product information
- MTBF Summary X2 pro, X2 control, X2 motion, X2 marine
- X2 export control and dual use
- X2 Letter of Volatility
- Battery test summary – X2 pro, X2 control, X2 marine
- Release notes PIEN344D / Last minute notes PIEN345D
Software
- AdAuth – iX user authentication with LDAP in domain / Active Directory
- iX Developer SP7 – 2.47.473 Software
- SqlProxy – Connects iX Panels transparently to SQL Server
- Remote Access Viewer v1.5.4, for Exter/E1000 – TxA/TxB/TAxx – X2 panels
Program examples/Start-up
- X2 Date time picker script
- IX alarm info request lookup in pdf by page index
- Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
- Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
- IX X2 Backlight \ screensaver ON Event
- iX Templates for E-key and X-Key
- Add Tags to Tagmonitor by script
- Ping from IX x2 terminal
- iX Developer – Top10 Alarm list, based on count and/or duration
- G Series, GT-5112 Program example X2 Control and GN-9386
- G series, GT-5112 Program example X2 Control and GN-9289
- G Series, GT-5112 Program example X2 Control and GN-9273
- G series, X2 Control, Parameter Set of I/O Modules connected to GN-9289 or GN-9273
- G series, X2 Control, Example with GN-9386 (EtherCAT)
- G series, X2 Control, Example with GN-9289
- G series, X2 Control, Example with GN-9273
- Program example CANOpen X2 Control – GN-9261 – BCS-XP325
- Program example CODESYS and iX: X2 Control communication with BFI-P2/BFI-H3 by Modbus TCP
- Program example CODESYS and iX: X2 Control communication with BFI by Modbus RTU
- Program example CODESYS and iX: X2 Control communication with BFI by EtherCat
- Program example CODESYS and iX: X2 Control communication with BFI by CANopen
- StartUp Program Example X2 control – BSD ver 3.31
- X2 control StartUp Guide Basic Settings SUEN284
- X2 Control (image 1.4 b581), StartUp Document and Links (Obsolete)
- X2 Control (image 1.2 b508), StartUp Document and Links (Obsolete)
- Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
- Quick Start Guide, MELSEC iQ-R Ethernet – X2 series SUEN00406
- Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
- Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series (SUEN00402)
- Sequence example BSD servo X2 control (iX/BCS Tools)
- X2 control / X2 marine SC / X2 extreme SC / BoX2 pro SC / BoX2 extreme SC with CODESYS (all image versions) – Startup, recommendations and limitations (SUEN00392)
Information document
Configuration files
- EDS file for CiX-CAN and X2
- X2 control CODESYS device XML, v3.5.10.10.1 (Obsolete)
- X2 control / X2 extreme SC / X2 marine SC / BoX2 pro SC / BoX2 extreme SC, CODESYS Device XML 3.5.13.30.1 (Current version)
- GSD files for CiX-DP Profibus module
System program
- X2 control image 1.2 b508 (Obsolete)
- X2 control / X2 marine SC / BoX2 pro SC image V2.0 b775 (Obsolete)
- X2 control / X2 marine SC / BoX2 pro SC image V2.1.1 build 906 (current version)
- CODESYS Runtime v3.5.10.10_16 (Obsolete)
- X2 pro – X2 control – Image V1.3b569 (Obsolete)
- CODESYS Runtime v3.5.10.10_5 (Obsolete)
- X2 control / X2 marine SC / X2 extreme SC / BoX2 pro SC / BoX2 extreme SC CODESYS Runtime 3.5.13.30 Patch 7 (obsolete)
- X2 control / BoX2 pro SC CODESYS Runtime 3.5.13.30 Patch 12 (Current version)
- X2 pro / X2 marine / X2 control – Image V1.4 b581 (Obsolete)