X2 base 10 v2 HP
10” HMI with iX runtime
-
1024 × 600 pixel (17:10)
-
TFT-LCD touch screen
-
2 × Ethernet, 6 × serial, 2 × USB as standard
-
Operating temperature -10° to +50° C
-
CE, FCC, UL approvals
Facts
General description
Part number | 630009610 |
Life cycle status | Active |
Warranty | 2 year |
Certifications
General | CE, FCC, UL 61010-2-201 |
Safety | UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201 |
Mechanical
Mechanical size | 290 x 193 x 40mm |
Panel Mount | |
1million finger touch operations | |
Touch type | Resistive |
Cut-out size | 275 x 177mm |
Weight | 0.86 kg |
Housing material | Plastic (PC+ABS), Gray |
Buzzer | No |
LED | No |
Power
Input voltage | 24 V DC (18 to 32 VDC) CE: The power supply has to be conform with the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supply has to be conform with the requirements for class II power supplies. |
Power consumption (max) | 8.1 W |
Input fuse | Internal DC fuse |
CPU | ARM Cortex A8 1000MHz |
RAM | 512 MB |
FLASH | 2 GB |
Display
Size diagonal | 10.1″ diagonal |
Resolution | 1024 × 600 pixel (17:10) |
Backlight | LED Backlight |
Backlight life time | 30000 hours |
Backlight brightness | 350 cd/m² |
Backlight dimming | Industrial Dimming |
Display type | TFT-LCD with LED backlight |
Digtal IO
Digital output | No |
Serial communication
Number of serial ports | 2port9pinDsub, 1port3pinScrew |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS 485 |
Serial port 4 | RS 232 |
Serial port 5 | RS422/485 |
Serial port 6 | RS 485 |
Ethernet communication
Number of Ethernet ports | 2 |
Ethernet port 1 | 1×10/100 Base-T (shielded RJ45) |
Ethernet port 2 | 1×10/100 Base-T (shielded RJ45) |
Expansion interface
Expansion port | No |
SD card | Yes |
USB | 2 |
Environmental
Operating temperature | -10°C to +50°C |
Storage temperature | -20°C to +60°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP65, NEMA 4X/ 12 and UL 50E Type 4X/ 12 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Drivers
ABB – COMLI Master (5.7.2) |
ABB – COMLI Slave (4.11.0) |
ABB – TotalFlow (5.2.1) |
Allen Bradley – ControlLogix Ethernet IP (4.24.1) |
Allen Bradley – DF1 (5.8.0) |
Allen Bradley – DH485 (4.6.2) |
Allen Bradley – MicroLogix Ethernet (5.6.0) |
Allen Bradley – SLC5/PLC5 Ethernet (5.4.0) |
Altus – Alnet I (5.8.0) |
Animatics – SmartMotor (5.2.1) |
Beckhoff – ADS (5.12.1) |
Beckhoff – ADS Symbolic (4.7.0) |
Beijer Electronics – iX Demo (4.4.0) |
Beijer Electronics – Macro driver (4.0.7) |
Bernecker + Rainer – Mininet (5.6.0) |
BoschRexroth – IndraDrive C (5.2.1) |
CODESYS – ARTI v2.x, v3.x (4.8.0) |
CODESYS – SoftControl Direct Access (4.4.0) |
Cognex – InSight (5.2.2) |
Control Techniques – Unidrive (5.3.1) |
CTC – Serial Binary (5.4.2) |
Delta – PLC Modbus ASCII (5.6.0) |
Emerson – Modbus Master RTU/ASCII (5.4.0) |
Eurotherm – Easy Serial 631 (5.1.1) |
Fatek – Facon (5.10.0) |
Galil – DMC (5.2.2) |
GE Fanuc – Ethernet SRTP (5.5.0) |
GE Fanuc – SNPX (5.6.1) |
Gidding & Lewis – Motion control (5.4.0) |
IAI – Xsel (5.4.1) |
Idec – Computer Link (5.8.0) |
Johnson Control – JCONTROL (5.2.1) |
KEB – COMBIVERT (5.4.0) |
Keyence – KV-series (5.6.0) |
Koyo – DirectNET (5.5.0) |
Koyo – K Sequence (5.3.1) |
Lenze – LECOM A/B (5.6.0) |
LS Industrial System – Glofa (5.3.0) |
LS Industrial System – Master K (5.4.0) |
Matsushita – MEWTOCOL-COM (5.9.2) |
Mitsubishi Electric – Alpha2 (5.7.0) |
Mitsubishi Electric – A-series (C24) (5.6.0) |
Mitsubishi Electric – A-series (CPU) (5.10.0) |
Mitsubishi Electric – A-series (E71) (5.4.0) |
Mitsubishi Electric – Freqrol FR-A PLC (5.8.2) |
Mitsubishi Electric – FX Series ADP/BD (5.10.0) |
Mitsubishi Electric – FX Series ENET (5.4.1) |
Mitsubishi Electric – FX Series Serial (5.16.0) |
Mitsubishi Electric – MC Protocol (5.11.4) |
Mitsubishi Electric – MR-J2/MR-J3-T MELSERVO (5.9.0) |
Mitsubishi Electric – QnA/Qnn Serial (5.10.0) |
Mitsubishi Electric – QnA/Qnn (C24) (5.5.0) |
Mitsubishi Electric – Q-Series Ethernet (E71) (5.5.0) |
Modicon – Modbus Master (5.19.4) |
Modicon – Modbus Slave RTU/TCP (4.20.2) |
NEMA0183 – NEMA 0183 (4.6.0) |
Omron – Ethernet IP (4.3.3) |
Omron – FINS (5.9.5) |
Omron – Host Link (5.6.0) |
Regin – EXOline (5.3.2) |
SAIA – S-BUS Serial/Ethernet (5.7.0) |
Schneider Electric – Modbus (5.3.0) |
Schneider Electric – TSX Uni-Telway (4.5.3) |
Siemens – S5 PG/AS511 (5.4.0) |
Siemens – S7 200 PPI (5.8.5) |
Siemens – S7 over TCP (S7-200/300/400/1200/1500) (4.18.0) |
Siemens – MPI (HMI Adapter) (5.7.0) |
WAGO – Modbus TCP (5.10.0) |
Vigor – M/VB-Series (5.6.0) |
Yamaha – VIP (5.2.1) |
Yaskawa – Memobus Master (5.7.0) |
Yokogawa – FA-M3 (5.6.0) |
Smart Engineering Resources
Resources
Knowledge
- IX otf and ttf fonts
- iX Developer SP7 – 2.47.473 Release information
- Driver MODICON Modbus Slave: Command XDNCW
- Windows CE versions, X2, iX, E1000
- Creating a custom Welcome Screen \ startup screen on a X2 pro operator panel
- Google Gmail end suport for ” less secure apps ” ends may 30 2022
- iX – SMTP – Using Gmail servers using App password
- When are Data deleted from the ix x2 database / backup restore database
- OPC ua settings in Phoenix plxnext engineer
- Image Sticking
- Best Practice Database on SD card or flash memory
- Driver Allen Bradley DF1: Behövs 1747-KE kommunikationsmodul ?
- Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411
- Max number of recipe items / tags
- Convert from Exter/E1000 To X2 Series
- X2 pro / X2 marine / BoX2 pro image V2.1 HF b909 (current)
- X2 Preemptive maintenance
- X2 image – Update EBOOT require SD card to be formatted to FAT16/FAT32
- X2 pro (SC) / X2 marine (SC) / X2 extreme (SC) / BoX2 base / BoX2 pro (SC) / BoX2 extreme (SC), Battery replacement
- X2/BoX2 script Access to the USB ports
Manuals
- iX Developer SP7 – 2.47.473 Reference Manual
- iX Developer SP7 – 2.47.473 User guide
- X2/Box2 image manual MAEN205
- X2 base V2 Serial interface mapping
- Image manual X2 base V2, MAEN352
- Installation manuals X2 base 10 /10 HP v2
Certificates
- DoC ECCN for X2 series HMI
- SDoC Green Passport
- Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
- Manufacturer declaration: X2 base v2 UKCA Declaration of Conformity
- CE Manufacturer declaration X2 base v2
- CE certificate x2 base 10 v2 HP
- KCC certificate X2 base 10 v2 HP
- FCC certificate x2 base 10 v2 HP
Drawings
- Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
- 3D drawing X2 base 10 v2 HP
- Outline drawing X2 base 10 v2 (HP)
Drivers
Brochures
Product information
- MTBF Summary X2 pro, X2 control, X2 motion, X2 marine
- X2 export control and dual use
- X2 Letter of Volatility
Software
- AdAuth – iX user authentication with LDAP in domain / Active Directory
- iX Developer SP7 – 2.47.473 Software
- SqlProxy – Connects iX Panels transparently to SQL Server
- Remote Access Viewer v1.5.4, for Exter/E1000 – TxA/TxB/TAxx – X2 panels
Program examples/Start-up
- X2 Date time picker script
- IX alarm info request lookup in pdf by page index
- Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
- Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
- IX X2 Backlight \ screensaver ON Event
- iX Templates for E-key and X-Key
- Add Tags to Tagmonitor by script
- Ping from IX x2 terminal
- iX Developer – Top10 Alarm list, based on count and/or duration
- Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
- Quick Start Guide, MELSEC iQ-R Ethernet – X2 series SUEN00406
- Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
- Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series (SUEN00402)